Sign In | Join Free | My himfr.com
Home > Battery Testing Machine >

Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation

KingPo Technology Development Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation from wholesalers
     
    Buy cheap Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation from wholesalers
    • Buy cheap Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation from wholesalers
    • Buy cheap Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation from wholesalers
    • Buy cheap Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation from wholesalers

    Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation

    Ask Lasest Price
    Brand Name : KingPo
    Model Number : KP-8210
    Certification : iso9001
    Price : To be quoted
    Payment Terms : TT
    Delivery Time : 35 working days
    Supply Ability : 3 sets per month
    • Product Details
    • Company Profile

    Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation


    Forced Internal Short Circuit Tester For Battery


    Product type: KP-8210


    Introduction:


    This machine is suitable for conducting mandatory internal short circuit and battery compression test at a certain environmental temp. according to latest requirement of IEC62133 and Japanese industrial standard JIS C 8714:2007.Test chamber’s material is stainless steel with good temperature uniformity and exhaust function.

    Control system:PLC touch screen menu type operation;voltage data acquisition frequency:100t/s;Set up programmable test pressure through PLC:pressure holding time,measured pressure,battery voltage,battery temperature and rate of pressure drop.


    Standard basis: IEC62133-2012, JIS C 8714:2007, IEC62281-2012.


    1. Perfect structure:

    Arc-shaped and sprayed surface;high-quality appearance;plane handle with no counterforce;easy operation and reliable performance;

    2. Bright and wide viewing window:

    Double-layer vacuum film coated window and philips energy-saving fluorescent lamp;no need of wiper defogging to keep clear observation

    3. Advanced and reliable refrigeration controller system:

    Original imported European and American hermetic compressor using environmental refrigerant and world famous components as well as imported LED push-button controller.

    4. Blackout stop,cooling,heating function;

    5. Breakdown and test finish alert.


    Pressure,Displacement,Volatge and Temperature Test system


    1. power acquisition system:

    American high precision AMCELL/ SUNCELL power sensor with 100KG capacity and power within ±0.5%F.S.

    2. capacity segment:

    (1) 7 grades:×1,×2,×5,×10,×20,×50,×100;

    (2) adopt high precision 24bitsA/D with sampling frequency of 200Hz

    3. dynamical system:

    (1) Panasonic AC servo;

    (2) Panasonic AC driver;

    (3) worm reducer;

    (4) Taiwan high precision ball screw and linear guide rail

    4. controller system:

    (1) PLC control mode with higher accuracy;

    (2) speed control range:0.01~20MM/S;error within 1%;

    (3) The intermediate plate has function of quick coarse tuning and slow fine tuning;

    (4) Return back to the original point and preserve it automatically

    5. display method:PLC touch screen

    6. test space:

    (1) width:200mm(standard);

    (2) valid displacement:100mm(not including fixture)(standard)

    7 . Displacement

    (1) encoder 2000P/R with 4 times accuracy improvement;

    (2) American PASO encoder with strong anti-interference;

    (3) analytic displacement:0.001mm;

    8. voltage control and acquisition:

    (1) real-time voltage data acquisition ranging 0-10V DC;

    (2) voltage display accuracy:0.1 mv;sampling rate:100t/s;

    (3) user-defined voltage measuring range.When PLC reaches the required data(e.g. rop to50mv),device stops operation.

    9. temperature acquisition system:

    (1) automatic acqusition battery surface temp.with sampling rate at 2t/s;

    (2) Derive data from RS232 serial port.

    10. Safety device:

    (1) overload emergency stop device

    (2) up&down stroke limit device

    (3) automatic breakdown stop function


    Technical Parameter


    ModelKP-8210

    Temperature Chamber

    Parameter

    Temp. Range0℃~ +100℃(controllable)
    Heating RateAverage 3℃/min(from 0℃ to 100℃. Non liner, no load)
    Cooling RateAverage 1℃/min(from 100℃ to 0℃, Non liner, no load)
    Inner Chamber DimensionW600 X H750 X D500 MM
    External Chamber DimensionW1500 X H1750 X D1000MM

    Inner Short Circuit

    Main Technical Parameters

    Max. Loading200KG
    Resolution1/10000
    Force Accuracy≤0.5%
    Force magnification7 Segment auto change
    Displacement Resolution1/1000
    Displacement Accuracy≤0.5%
    Speed Range0.01-20MM/S
    Effective Range0 ~ 150mm
    Max. Testing Space300X300MM(Able for special customize according customer requirement)
    Voltage Sampling Range0—20V
    Voltage Resolution1MV
    Voltage Sampling Frequency100HZ
    Control SystemServo Control System

    Temperature controller:


    1. range: 0℃~100℃;

    2. analytic accuracy:temp±0.1℃;

    3. fluctuation:±0.3℃;

    4, uniformity: ±2℃;

    5. Extreme:0℃;

    6. Heating rate: average 3℃/min(rise from 0℃ to 100℃;non-linear no-load;average heating speed);

    7. Cooling rate: average 1℃/min(drop from100℃ to 0℃;non-linear no-load;average heating speed);

    8. Interior :W400×H500×D400mm;

    9. External material:stainless steel mirror with strengthened bottom

    10. Exterior:W1050×H1950×D1900mm;


    Internal Short Circuit Test System:


    1. max load: 100KG;

    2. load resolution: 1/10000;unit conversion: kg, lb,N

    3. load accuracy: ≤0.5%

    4. max power mutiple: 7 grades with automatic conversion ;

    5. Stroke resolution: 1/1000;

    6. Stroke accuracy : ±0.05 mm;

    7. speed range: 0.01—20MM/S adjustable,general test speed:0.1mm/S;

    8. valid stroke: 100MM(not including fixture);

    9. max test surface: 200×200MM(customized);

    10. voltage sampling rate: 0—20V(customized);

    11. voltage resolution ratio: 0.1MV;

    12. voltage sampling rate: 100t/s;

    13. compression panel material: stainless steel;affixed Telflon tape;corrosion proof

    14. head size: 10*10*15mm;stainless steel;ficture for short circuit;  

    15. head material: 1 NBR(edge10mm;thick 2mm,1 acryl(edge 5mm;thick 2mm)error:±0.1 mm

    16. compression movement:from top to bottom 

    17. steps: Use standard pressurization tool to press on the part with small nickel of single cell at 0.1mm/S.At the same time,monitor voltage change of voltage acquisition’s output terminal(voltage sampling rate:100t/s) .When there are more than 50mV voltage drop or reaching the required pressure(cylindrical battery 800N,square/rhombic battery 500N/ 400N),immediately stop the pressurization tool and keep for 30s and then remove pressure.


    Standard Compliance- Battery internal short circuit test machine

    Impact Test Standard

    UL1642 Lithium Batteries

    UL2054-2005 Household and Commercial Batteries

    UN38.3 Lithium ion battery safety testing

    GB/T 18287-2000 General specification of lithium-ion battery for cellular phone

    SJ/T 11169-1998 Standard for lithium batteries

    YD 1268- 2003 The safety specification and test method for lithium batteries and charger

    SJ/T 11170-1998 Standard for household and commercial batteries

    Crush Test Standard:

    GB/T 2900.11-1988Terminology of (secondary) cell or battery : crush

    YD 1268- 2003 The safety specification and test method for lithium batteries and charger : crush

    SJ/T 11169-1998Standard for lithium batteries:crush

    UL 1642Lithium batteries : crush

    GB/T 8897.4-2002Primary batteries-Part 4: Safety of lithium batteries

    SJ/T 11170-1998 Standard for household and commercial batteries- crush test

    YDB 032-2009 Back-up lithium-ion battery for telecommunications

    UL 2054 Household and Commercial Batteries

    QB/T 2502-2000 General specification of lithium-ion battery

    Nail penetration standard

    GB/T 18332.2-2001Nickel-metal hydrate batteries of electric road vehicles nail penetrations

    MT/T 1051-2007 Lithium-ion batteries for cap lamp nail penetration test


    Features- Battery internal short circuit test machine

    1 .The wire enclosed with metal fire-proof cover, which is available to prevent the flame during testing process.

    2 .Lighting system is designed to observe the internal testing process;

    3 .Nail Penetration/Crush Velocity with controllable range of 10~80mm/s;

    4 .Nail Penetration/Crush Force controllable within range from 250N to 13KN ,meet different standards;

    5 .Wire hole provides a possibility to test internal temperature or air pressure while vent hole with air blower can discharge the exhaust air.

    6 .Control system employs independent control cabinet & separated with the test chamber with a distance 1-2 meter, which can reduce the noise and improve safety.


    Standard configuration:

    1 sensor;

    1 set of standard pressurization device;

    2 sets of standard compression head;

    Another 5 stainless steel compression head;

    5 pieces of test-used nickel(copy of nickle calibration certificate)

     

    Basic component:

    Sensor------American SUNCELL;

    Dynamical motor and driver------German ALPHA;

    Temperature controller-----Korean imported TEMI880 ;

    Refrigeration compressor-----French “Taikang”


    Quality Highly Integrated Battery Forced Internal Short Circuit Tester IEC recommendation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: KingPo Technology Development Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)