Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | Kingpo |
Model Number : | IEC60601-1-Figure 33 |
Certification : | iso9001 ce |
Price : | To be quoted |
Payment Terms : | T/T |
Supply Ability : | 10 pcs per month |
Delivery Time : | 7 working days |
Body Upper-Carriage Module-IEC60601-1-Figure 33 , IEC60601-clause 9.8.3.3 loading tester
9.8.3.3 * Dynamic forces due to loading from persons
Where dynamic forces (due to sitting down, standing up, PATIENT
handling PROCESS or the like) can be exerted on ME equipment parts
intended to support or suspend a PATIENT or OPERATOR in NORMAL USE,
the ME EQUIPMENT shall maintain BASIC SAFETY and ESSENTIAL
PERFORMANCE.
Compliance is checked by the following test:
Prior to performing this test, the PATIENT support/suspension
system is positioned horizontally in its most disadvantageous
position in NORMAL USE.
For the area of support/suspension where a PATIENT or OPERATOR can
sit, the top reservoir of the body upper-carriage module described
in Figure 33 is loaded with the appropriate mass to obtain the SAFE
WORKING LOAD representing the PATIENT or OPERATOR as defined in the
ACCOMPANYING DOCUMENTS. The body upper-carriage module with
appropriate mass is dropped from a distance of 150 mm from the
lowest edge of the foam to the area where a PATIENT or OPERATOR can
sit. BASIC SAFETY and ESSENTIAL PERFORMANCE shall be maintained.
NOTE Examples of damage that can affect BASIC SAFETY include the
reduction of CREEPAGE DISTANCES and AIR CLEARANCES below those
specified in 8.9, access to parts that exceed limits in 8.4, or
access to moving parts which could cause HARM.
Assessment criteria that can be useful in determining if this test
has resulted in a loss of BASIC SAFETY include:
– those in Clause 8 and 11.6;
– the dielectric strength test as specified in 8.8.3 to evaluate
the integrity of solid providing a MEANS OF PROTECTION; and
– measurement of CREEPAGE DISTANCES or AIR CLEARANCES to compare
the values with the minimum distances
specified in 8.9. Small chips that do not adversely affect the
protection against electric shock or moisture can
normally be ignored.
Parameters:
Model | KP-601A |
Name | loading tester |
Drop height | 150 mm |
Test sample size | 1700(H)*1200(W)mm Max |
Load weight | 200kg Max (by adding steel balls) |
Electrical control | MITSUBISHI PLC, 7 Inch Touch screen |
Power supply | 220V 50HZ |
ISO17025 Certificates | test report issued by internationally recognized laboratory with ilac.MRA mark. |
Equipment picture
![]() |