    IEC 60601-1 Grips And Other Handling Devices-7 Cm Strap Tester

    Ask Lasest Price
    Brand Name : KingPo
    Model Number : KP-HD38-1
    Certification : calibration cert
    Payment Terms : T/T
    • Product Details
    • Company Profile

    IEC 60601-1 Grips And Other Handling Devices-7 Cm Strap Tester

    IEC 60601-1Grips and other handling devices-7 cm strap tester
    Carrying handles or grips furnished on PORTABLE ME EQUIPMENT shall withstand loading as described in the following test:
    The handles and their means of attachment are subjected to a force equal to four times the weight of the ME EQUIPMENT in any direction of NORMAL USE and transport.
    If more than one handle is furnished on PORTABLE ME
    EQUIPMENT , the force is distributed between the handles. The distribution of forces is determined by measuring the percentage
    of the ME EQUIPMENT weight sustained by each handle with the ME
    EQUIPMENT in the normal carrying position. If the ME EQUIPMENT is furnished with more than one handle but is so designed that it can readily be carried by only one handle, then each handle is to be
    capable of sustaining the total force.
    The force is applied uniformly over a 7 cm length of the handle at the centre, starting at zero and gradually increasing so that the test value will be attained in 5 s to 10 s and maintained for a period of 1 min.
    Handles that break loose from the ME EQUIPMENT or exhibit any permanent distortion, cracking or other evidence of breakdown constitutes a failure.

    TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

    IEC 60601-1:2005 + Am.1:2012

    Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


    “R” Required

    “S” May be subcontracted, see OD 2012

    “SPTL” Specialized Facility, see IECEE 02-2

    “W” Witness testing in the categories “MED” and “MEAS”

    “3PPS” Three Phase Power Supply required


    ClauseMeasurement/testingTesting / measuring equipment / material neededSubcontracting
    4.11Power input

    Suitable devices for the voltage, current/power and frequency

    Supply: 1 phase and 3 phase variacs


    R
    5.3Ambient temperature, humidity, atmospheric pressure

    Suitable devices for recording ambient temperature, humidity, atmospheric pressure


    R
    5.7Humidity preconditioning treatment

    Environmental conditions: Climate chamber controlling temperature and humidity


    R
    5.9.2Accessible parts

    Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7)


    R
    7.1.2Legibility of markings

    Illuminance meter


    R
    7.1.3Durability of markings

    Distilled water, ethanol (96% pure), isopropyl alcohol , timer / stop watch


    R
    8.4.2Accessible parts including applied parts

    Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N)


    R

    8.4.3,

    8.4.4

    Limitations voltage and energySuitable oscilloscope recorder /set-up & RCL meterR
    8.5.5.1Defibrillation protection

    5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope


    S
    8.5.5.2Energy reduction test

    The test circuit according to Figure 11, oscilloscope, oscilloscope leads


    S
    8.6.4Impedance and current-carrying capability

    Current source (25 A minimum, 50 or 60 Hz, 6 V maximum)


    R
    8.7Leakage currents and patient auxiliary currents

    Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20)


    R
    8.8.3Dielectric strength

    High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch / timer


    R
    8.8.4.1 a)Ball pressure test

    Test equipment according to IEC 60695-10-2


    R
    8.8.4.2Resistance to environmental stress

    Apparatus for ageing rubber in oxygen


    S
    8.9Creepage distances and air clearances

    Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6)


    R
    8.9.1.7Material groups classification

    Test equipment according to IEC 60112


    S
    8.9.3.4Thermal cycling

    Heating cabinet


    R
    8.11.3.5Cord anchorage

    Force gauge (at least 100 N), torque gauge (at least 0.35 Nm)


    R
    8.11.3.6Cord guards

    Weights, angle gauge, radius gauge


    R
    9.4Instability hazards

    5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch / timer


    R
    9.5.2Cathode ray tubes

    The relevant tests of IEC 60065, Clause 18.


    S
    9.6.2.1Audible acoustic energy

    A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1


    S
    9.6.3Hand-transmitted vibration

    Measurements are made in accordance with ISO 5349-1.


    S
    9.7.5Pressure vessels

    Hydraulic pressure test apparatus


    S
    9.8Hazards associated with support systems

    Weights or load cell, 0.1 m2 test surface, stop watch / timer, human body test mass (Figure 33)


    R
    10.1X-radiation

    Radiation meter


    S
    10.3Microwave radiation

    Radiation meter


    S
    10.4LasersTest equipment according to IEC 60825-1S
    11.1Excessive temperatures

    Temperature indicator/recorder suitable for this function and

    thermocouples, 4 wire resistance unit, test corner, variac


    R
    11.2Fire prevention

    Spark ignition test apparatus (Figure 34), oxygen gas analyzer


    S
    11.3Constructional requirements for fire enclosuresFV tests specified in IEC 60695-11-10S
    11.6.2Overflow

    15° inclined plane or inclinometer or trigonometric calculation, stop watch / timer, high voltage tester


    R
    11.6.3Spillage

    Flask or graduated cylinder, stop watch / timer


    R
    11.6.5Ingress of water or particulate matter

    Classification tests of IEC 60529


    W
    11.6.6Cleaning and disinfection

    Dielectric strength and leakage current tests as appropriate


    R
    11.6.7Sterilization

    Sterilisation to client specification


    S
    13Hazardous situations and fault conditions

    stop watch / timer, voltmeter, ammeter, temperature indicator / recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth


    R
    15.3Mechanical strength

    Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven


    R
    15.4.2Temperature and overload control devices

    Positive temperature coefficient devices (PTC’s) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17


    S
    15.4.3.4Primary Lithium batteries

    Performance of the tests identified in IEC 60086-4


    S
    15.4.3.4Secondary Lithium batteriesPerformance of the tests identified in IEC 62133S
    15.4.6Actuating parts of controls

    Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch / timer


    R
    15.4.7Cord-connected hand-held and foot-operated control devices

    Force gauge (minimum1 350 N), 30 mm diameter test tool, stop watch / timer


    R
    15.4.7.3Entry of liquids

    Classification tests of IEC 60529


    W
    15.5.1.1Transformers

    Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads


    R
    15.5.2Dielectric strength

    5x voltage / 5x frequency dielectric strength test fixture, stop watch / timer


    R
    16.6Leakage currents

    As in sub-clause 8.7


    R
    A 10.4Light emitting diodes (LEDs)

    As specified in IEC 62471


    S
    GProtection against hazards of ignition of flammable anaesthetic mixtures

    4 mm & 12 mm diameter test rods, timer / stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, ether/oxygen mixture (ether volume percentage 12,2 % ± 0,4 %),test apparatus for flammable mixtures (Figure G.7),


    S
    G.4.3Prevention of electrostatic charges

    antistatic material testing according to ISO 2882


    S
    LInsulated winding wires for use without interleaved insulationSample is preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron.S